This adapter integrates with APsystems EZ1 microinverters using the device’s local HTTP API (port 8050).
It allows reading real‑time inverter data and controlling certain device parameters.
- Read realtime power and energy values
- Read device information (firmware, SSID, IP, etc.)
- Read alarm states
- Set MaxPower
- Set On/Off state
- Support for multiple devices in one adapter instance
- HTTP timeout + retry logic
- Optional email alerting on repeated errors
- Includes a VIS2 widget for monitoring and control
APsystems EZ1 product page:
https://apsystems.com
Install via ioBroker Admin:
Adapters → Search “apsystems-ez1” → Install
or via CLI:
iobroker install iobroker.apsystems-ez1
The adapter supports multiple devices via a JSON array:
Example:
[
{ "name": "Roof", "ip": "192.168.1.50" },
{ "name": "Garage", "ip": "192.168.1.51" }
]- Interval in seconds between polls
- Default: 30
- HTTP timeout in milliseconds
- Default: 5000
- Number of retry attempts
- Default: 2
- IP Port Number of device
- Default: 8050
- Optional email address for persistent error alerts
- Requires local sendmail
All states are created under:
apsystems-ez1.<instance>.devices.<DeviceName>.*
| State | Type | Description |
|---|---|---|
| deviceId | string | Device ID |
| devVer | string | Firmware version |
| ssid | string | Connected WiFi SSID |
| ipAddr | string | Device IP address |
| State | Type | Description |
|---|---|---|
| output.p1 | number | Power channel 1 (W) |
| output.p2 | number | Power channel 2 (W) |
| output.p | number | Total power (W) |
| output.e1 | number | Energy channel 1 (kWh) |
| output.e2 | number | Energy channel 2 (kWh) |
| output.e | number | Total energy (kWh) |
| output.te1 | number | Lifetime energy channel 1 |
| output.te2 | number | Lifetime energy channel 2 |
| State | Type | Write | Description |
|---|---|---|---|
| control.maxPower | number | yes | Set Max Power (W) |
| control.onOff | boolean | yes | Turn inverter on/off |
| State | Type | Description |
|---|---|---|
| alarm.og | boolean | Off‑grid alarm |
| alarm.isce1 | boolean | DC1 short circuit |
| alarm.isce2 | boolean | DC2 short circuit |
| alarm.oe | boolean | Output fault |
A VIS2 widget template is included under:
vis2/ez1-control
It displays:
- Power & energy values
- Alarm states
- MaxPower & On/Off controls
You may need to adjust the instance ID inside the widget.
The adapter uses the following endpoints:
GET /getDeviceInfo
GET /getOutputData
GET /getMaxPower
GET /getAlarm
GET /getOnOff
GET /setMaxPower?p=VALUE
GET /setOnOff?status=0|1
Install dependencies:
npm install
Run tests:
npm test
Run adapter in dev‑server:
dev-server watch
Releases are handled via GitHub Actions. Push a tag like:
v0.1.7
and a new release will be published automatically.
- Fix review findings
- release 0.2.3 to npm
- Fix warning at startup of validator function
- First pre‑release version
- First hardware‑tested version
- Refactor release script, add i18n step, avoid duplicates
- Fix JSON parsing and repository checker issues; add dminUI config and icons
- Initial release
Haining Zhi
GitHub: https://github.com/zhihaining
MIT License Copyright (c) 2026