Zonnepanelen — APsystems ECU-3 for Home Assistant

Home Assistant integration that monitors a local APsystems ECU-3 solar energy communication unit. It polls the ECU's built-in web interface over HTTP on your LAN — no cloud account, no internet required, no credentials stored.

Tested against Home Assistant 2025.5 – 2026.4.

What it does

  • Discovers every microinverter reported by the ECU and creates an entity per electrical measurement it exposes.
  • Exposes the system-wide totals from the ECU's index page.
  • Adds an aggregated health problem binary sensor so you can alert on missing or underperforming inverters without wiring up a template yourself.
  • Supports reconfigure (change the ECU's IP when your router reshuffles the DHCP lease) and diagnostics download for easy bug reports.

Entities

System device (one per ECU):

Entity Description
sensor.<n>_current_power System power, W
sensor.<n>_daily_energy Energy produced today, kWh
sensor.<n>_lifetime_energy Cumulative energy, kWh
sensor.<n>_online_inverters Number of inverters the ECU currently sees
sensor.<n>_signal_strength ECU ↔ inverter signal, raw value from the ECU (typically 0–5, bars)
binary_sensor.<n>_problem See Problem detection below

Per-panel device (one per microinverter, linked to the system device):

Entity Description
sensor.<n>_panel_<id>_power Instantaneous output, W
sensor.<n>_panel_<id>_voltage AC voltage, V
sensor.<n>_panel_<id>_frequency Grid frequency, Hz (if reported)
sensor.<n>_panel_<id>_temperature Inverter temperature, °C (if reported)

lifetime_energy and daily_energy are suitable for the Energy Dashboard out of the box.

Problem detection

binary_sensor.<n>_problem turns on when any of the following holds:

  1. Missing inverters during daylight. At least N inverters are missing (default N = 2 against the session's high-water mark), AND we're inside the daylight window. The daylight window is defined as sun elevation ≥ 10° OR more than 60 minutes past today's local sunrise (and before sunset). This avoids alarms during a normal sunrise ramp-up. The threshold N is configurable via the options flow.
  2. Underperforming panel. Any panel is producing less than the configured threshold (default 10%) of the mean of the others, gated on that mean being at least 25 W (so morning ramp-up and overcast conditions don't generate noise). The threshold can be adjusted via the options flow — see Configuration below.

Optionally, the daylight window can be further gated on an illuminance (lux) sensor from another integration — useful to suppress false alarms on dark winter days when the sun is technically above 10° but actual production is negligible. See Options below.

The sensor returns unknown while the ECU is unreachable, so it doesn't false-fire during a brief network outage.

Useful attributes (for dashboards and automations):

  • problem_reasons — human-readable list of what's wrong right now.
  • missing_inverter_count, reporting_inverters, expected_inverters.
  • min_missing_inverters — the missing-inverter threshold in effect.
  • underperforming_panels — list of panel IDs currently below the ratio.
  • underperformance_percent — the threshold in effect (default 10).
  • excluded_panels — panel IDs the user has excluded from checks.
  • illuminance_entity — the optional lux sensor, or None.
  • min_illuminance — the lux threshold in effect, when an entity is set.
  • daylight_window_open — whether the missing-inverter check is active.

Requirements

  • Home Assistant ≥ 2025.5.
  • An APsystems ECU-3 that's reachable from your HA host over HTTP on port 80, with its web interface enabled.
  • HACS (optional but recommended for updates).

Installation

Via HACS (recommended)

The integration is not in the default HACS index. Add the GitHub repository as a HACS custom repository:

  1. Open HACS in Home Assistant.
  2. Click the ⋮ menu (top-right) → Custom repositories.
  3. Paste the repository URL: https://github.com/lancer73/apsystems-ecu3-zonnepanelen Category: Integration. Click Add.
  4. Find Zonnepanelen (APsystems ECU-3) in the HACS integrations list and click Download.
  5. Restart Home Assistant.
  6. Go to Settings → Devices & Services → Add Integration and search for Zonnepanelen.

Manual

  1. Copy the custom_components/zonnepanelen/ directory from this repository into <config>/custom_components/ on your HA instance so you end up with <config>/custom_components/zonnepanelen/.
  2. Restart Home Assistant.
  3. Settings → Devices & Services → Add Integration → Zonnepanelen.

Configuration

Everything is configured through the UI — there is no YAML schema.

During the initial config flow:

  • Host — your ECU's LAN IP or hostname (without http:// and without a path). Example: 192.168.1.42.
  • Name — the device name HA will display. Defaults to Zonnepanelen.
  • Update interval — seconds between polls, between 30 and 3600. Defaults to 300. The integration probes the ECU's / and /index.php/realtimedata endpoints during setup and refuses to create the entry if either fails.

Options

Open Settings → Devices & Services → Zonnepanelen → Configure to adjust the problem-sensor behaviour:

  • Update interval — seconds between polls (30–3600).
  • Minimum missing inverters to trigger — the problem sensor fires when at least this many inverters are missing (inside the daylight window). Default 2. Range 1–50.
  • Underperformance threshold (%) — a panel is flagged when its power drops below this percentage of the other panels' mean. Default 10. Lower values reduce false alarms from partial shading; higher values catch milder degradation earlier. Valid range: 1–100.
  • Illuminance sensor (optional) — an illuminance device-class sensor from another integration. When set, the daylight window only opens when both the sun-based check passes and this sensor reads at or above the threshold below. Useful to suppress false alarms on dark winter days when the sun is technically high enough but actual irradiance is negligible. If the configured sensor becomes unavailable, the integration falls back to the sun-only check and logs one warning per outage.
  • Minimum illuminance for problem window — threshold for the lux sensor (100–10000 lx). Default 700. Only applies when an illuminance sensor is selected; otherwise ignored.
  • Excluded panels — pick one or more panel IDs to exclude from the problem sensor. Excluded panels are dropped from both the underperformance check (not a candidate, not part of the reference mean) and the missing-inverter check (subtracted from the expected inverter count). Typical use: a microinverter with only one panel physically attached, where the unused channel reports 0 W permanently.

The panel picker only appears after the integration has had at least one successful poll, because panel IDs come from the ECU. If you open the options page on a brand-new entry before the first refresh has completed, the other fields still render — re-open it after the first poll to see the panel list.

The panel list shows the union of panels currently reporting plus any already excluded, so a panel can be un-excluded even while it is offline.

The lux gate is re-evaluated on each coordinator tick (same cadence as the ECU poll), not on each lux-sensor state change. This matches the rest of the sensor's evaluation model; expect up to one poll interval of lag between a lux change and the problem-sensor response.

Reconfiguring

If the ECU moves to a new IP or you want to change the scan interval without losing history:

  1. Settings → Devices & Services → Zonnepanelen → ⋮ menu → Reconfigure.
  2. Enter the new host/interval. History, statistics and Energy Dashboard wiring are preserved because the config entry (and therefore all entity IDs) stays the same. The flow will refuse to point an existing entry at a different ECU — remove the entry and add a new one if that's what you want.

Diagnostics

Settings → Devices & Services → Zonnepanelen → Download diagnostics produces a JSON blob with entry metadata, coordinator state, and the last parsed dataset from the ECU. The ECU's host is redacted by default, since diagnostics dumps are usually shared in public GitHub issues.

Networking & security

  • All communication is local HTTP on port 80. The ECU-3 doesn't offer HTTPS or authentication; this is consistent with other local solar integrations (Envoy, SolarEdge local API, …).
  • HA talks to the ECU directly — no data leaves your LAN.
  • HTTP requests time out at 10 seconds.
  • No credentials are stored anywhere. The host field accepts hostnames and IPv4/IPv6 literals only; full URLs are rejected.

Known limitations

  • The ECU's web interface occasionally returns an empty or malformed page. The integration keeps the previous poll's data, flips every entity to unavailable, and retries on the next tick — no stale "fresh-looking" readings.
  • The problem sensor's expected inverter count is an in-memory high-water mark that resets when HA restarts. After a restart the missing-inverter check needs one successful poll before it can fire.
  • New panels added to the ECU are picked up on the next coordinator refresh; no reload required. They are not automatically added to the excluded-panels list — if the new panel's second channel is also unused, add it via the options flow.
  • Parsing is regex-based against the ECU-3's HTML. A firmware update that changes the page layout will break parsing. File an issue with a diagnostics download attached if this happens.

Migration & upgrade notes

Entity unique_ids changed from zonnepanelen_<…> to entry-ID-scoped values in v2.0.0. The migration is automatic — history, statistics and Energy Dashboard wiring survive.

v2.0.0 had a bug where old device records were left behind as empty orphans after the migration. v2.1.1 adds a follow-up migration that removes those orphans automatically on the first HA restart after upgrade.

v2.2.0 lowered the default underperformance threshold from 25% to 10% and made it configurable. Existing installs pick up the new default on upgrade; no migration runs. If you were relying on the previous 25% behaviour, set the threshold to 25 via the options flow.

v2.3.0 made the missing-inverter threshold configurable and flipped the comparison semantic. Pre-2.3.0: fires on strictly more than 2 missing (i.e. 3+). 2.3.0+: fires on at least N missing, with N defaulting to 2 — which means 2+ now fires. To restore the old behaviour exactly, set Minimum missing inverters to trigger to 3 in the options flow.

Any automations that addressed the old devices by device_id need re-pointing — either at the new device or (preferably) at the entities by entity_id.

Troubleshooting

  • "Failed to connect" during setup. Check you can reach http://<host>/ and http://<host>/index.php/realtimedata from the HA host (e.g. curl). If your HA host is in a separate VLAN from the ECU, allow TCP/80.
  • Everything is unavailable. Check the Logs for Zonnepanelen (<host>): UpdateFailed — if it's ECU unreachable the ECU is down or on a different IP (use the Reconfigure flow). If it's ECU returned no parseable data, attach a diagnostics download to an issue.
  • Problem sensor fires every morning. The daylight window starts at 10° sun elevation OR 60 minutes past sunrise — if your site is heavily shaded at that time, the underperformance check can still pick up legitimately-dim panels. Either lower the underperformance threshold further in the options flow, configure an illuminance sensor with a suitable threshold, suppress the automation using the daylight_window_open attribute, or gate on a sun-elevation condition.
  • Problem sensor never fires in winter. If you've configured a lux sensor, check that its readings actually clear the configured threshold during daylight. On truly overcast winter days, peak indoor-measured lux can stay well below 700 lx even at solar noon — that's the point of the gate, but if it's suppressing real problems you want flagged, lower the threshold or remove the sensor. The daylight_window_open attribute and the illuminance_entity / min_illuminance attributes let you see what the sensor is doing.
  • Lux sensor went offline. The integration falls back to the sun-only check and logs one warning (Illuminance sensor … is unavailable; falling back to sun-based daylight window only). You won't get a fresh warning every poll — only one per failure episode. The warning repeats if the sensor recovers and then fails again.
  • One channel of a dual-inverter always flags. A microinverter with only one panel attached will report 0 W on its unused channel indefinitely. Add that panel ID to Excluded panels in the options flow. The panel ID is visible in the entity ID (sensor.<n>_panel_<id>_power) and as an entry in the binary sensor's underperforming_panels attribute.

Credits

Originally written by @lancer73. The ECU-3 web scraping is inspired by a community Python script referenced in the original repository.

License

MIT. See LICENSE in the repository root.

License

See LICENSE in the repository root.

About

Home Assistant Integration for the APSystems ECU-3 controller (the old powerline version)