I build optimization-based controllers for energy systems, and the measurement systems that let them run outside a model. MSc Mechanical Engineering, Purdue University (Ray W. Herrick Laboratories). Interests: model predictive control, system identification, building controls and demand flexibility.
LinkedIn · Google Scholar · ernestosandovalhdez@gmail.com
| Project | What it shows | Result |
|---|---|---|
| Wind, solar and battery sizing for an industrial load · MATLAB | Component-level PV, wind and battery models, with a year-long 5-minute simulation for every configuration | 14 turbines, 9,500 PV modules, 5.5 MWh: $81.2M saved over 10 years, 3.98-yr payback |
| Low-GWP refrigerants for a cold-climate heat pump · EES | ASHRAE load calculation, variable-speed compressor model, coil sizing, full-cycle performance | HSPF 12.4 / SEER 15; R-1234ze(E) has the highest heating COP at low ambient temperature |
| Wind supply sizing for a blue-ammonia plant · MATLAB | Wind-farm sizing against grid supply, plus plant techno-economics | 80 MW optimum cuts electricity cost 28%; LCOA $256/t |
| Temperature and concentration dependence of GaAs solar cells · MATLAB | I-V and quantum-efficiency analysis at 15–75 °C and 1–7 suns (University of Tokyo, 2023; code only, lab data not public) | Efficiency 17.0% → 14.8% from 15 to 70 °C; temperature is the dominant loss at every concentration |
Multi-zone predictive control for residential HVAC, MSc thesis, 2024–2026, advised by Prof. Kevin J. Kircher. I designed, commissioned and ran a two-layer supervisory MPC (24-hour horizon, CVXPY) for a variable-speed heat pump in an occupied 2,240 ft² house through a full heating season. I identified a 5R2C thermal model from 50,000+ sensor readings (0.07–0.10 °C RMSE on held-out data) and built the instrumentation for $1,708. Results: 11.5% less weather-normalized heating energy (95% CI 1.5–21.2%) against the manufacturer baseline, and 71% lower comfort-tracking error. Thesis, DOI 10.25394/PGS.32751594. Journal article in preparation.
The Future Below: Renewable-Powered Underground Data Hubs, Springer, 2026, pp. 243–250. A five-author feasibility study siting an underground data center against wind, solar and inactive-mine data; my part was the techno-economics and renewable integration. Underground chilled-water cooling cut cooling load 3.33× (23.6 → 7.1 kW). Eleven Vestas V110 turbines at a 46.98% capacity factor cover a 10 MW center's 87.6 GWh/yr. DOI 10.1007/978-3-032-07974-9_21.
Self-sustained Rankine-cycle pump prototype, senior capstone with Constellation Energy, 2024. Lead design engineer on a five-person team. I designed, built and tested a prototype that uses controlled pressure transients to recover thermal energy, over 50+ hours of testing: about 5% thermal energy recovery, with all functional and safety targets met. The analysis and results contributed to a patent application filed by the sponsor, on which the sponsoring engineer is the named inventor.
Python (CVXPY) · MATLAB · EES · OpenLCA · Zigbee sensor networks · time-series databases