Skip to content

About

Prompt-configured camera vision for SCADA. SAM 3.1 watches a drawn zone and publishes Clear, Active or Unknown over OPC UA, MQTT or REST.

Topics

Resources

Stars

0 stars

Watchers

0 watching

Forks

Repository files navigation

vLock-AI Vision

Set up camera vision with a prompt. SCADA gets one simple state per zone: Clear, Active or Unknown.

No model training and no vendor integrator: type what to watch, draw the area, and bind the tags over OPC UA, MQTT or REST. The main example is a restart permissive, where SCADA accepts a reset only while the zone reads Clear.

Demo

SAM 3.1 outlines the hand and the bottle, the zone goes Active, Ignition latches a stop and the printer pauses

Watch the full demo video

A person with a water bottle in front of a 3D printer, shown in an Ignition Perspective view. The bottle stands in for any object or person that should not be in a hazard zone.

  • Rule, zone A-101: hand overlaps the area AND bottle overlaps the area for 1 s.
  • Stop: a hand and a bottle are both in the drawn area on two fresh checks. State goes Active, Ignition latches a stop and sends the printer one Pause.
  • Clear: the hand and the bottle are not both in the area. State reads Clear and the print continues. After a stop, Clear alone restarts nothing.
  • Reset: System Reset is accepted only while State is Clear and Settled is true. It is refused while the zone reads Active, and from the first fresh check that sees the hand and bottle in the area again.

The problem

  • Light curtains detect crossing, not presence. A person steps inside, the curtain clears, someone resets, and the machine runs with them in it. The same applies to a person on a conveyor.
  • Interlocks get bypassed with jumpers and dummy wires.
  • Vision systems are closed vendor packages. The plant's own controls engineer can't change them.

What it does

  • Main use: a permissive before restart. SCADA accepts a reset only while the zone's rule reads Clear. A check takes seconds, so it is not a fast stop.
  • Clear is the last confirmed result of the configured rule, and it expires if no fresh check follows. It does not mean the zone is empty: with a person AND dog rule, a person alone reads Clear.
  • A lost camera, a failed check or a late result is Unknown, never Clear.
  • Plain status over OPC UA, MQTT or REST. No vendor integrator, no proprietary hardware.
  • Rules are prompts: name the object and draw the area. No retraining, no code changes.

What else it could watch, none of it tested: a stack light on a machine with no data connection, a pallet present, a bin full, a door open.

How it's different

Light curtain / interlock Vendor vision safety system vLock
Detects presence inside the zone, not just crossing No Varies by product Yes, on each check (2-4 s apart)
Tells who or what is there No Varies by product The objects named in the prompt, with a count
Rule change Rewire Vendor visit Edit a prompt
Who integrates Electrician Vendor integrator Your own SCADA developer
Output Safety relay Proprietary Open tags (OPC UA, MQTT, REST)
Safety certified Yes Yes NO

vLock combines camera vision and fixed SCADA tags in one public repository that a controls engineer can run and modify. The stop latch stays on the SCADA side.

How it works

flowchart LR
    CAM[Camera] --> SAM[SAM 3.1]
    SAM --> RULE[Fixed rule code]
    RULE --> STATE[State: Clear / Active / Unknown]
    STATE --> SCADA[Ignition]
    RULE -. optional .-> VLM[Muse Spark frame check]
    VLM -. advisory .-> TAG[VlmState tag]
Loading
  1. SAM 3.1 finds the objects named in the rule on the latest camera frame. It runs on a local NVIDIA GPU or through the Meta Model API.
  2. Fixed code compares the object outlines with the drawn area. A state change needs two matching fresh checks.
  3. Unknown is never Clear. A lost camera, a failed model call or a late result publishes Unknown with a Reason.

The rule in plain words and the drawn area on the camera view

Muse Spark can draft a rule from plain English, and a person approves it before it runs. The optional Muse frame check writes its answer to VlmState only. It never changes State.

Demo setup

Part Used in the demo
SCADA Ignition Perspective
Stand-in machine Bambu Lab P1S 3D printer
Camera Raspberry Pi 5 with a USB camera, 640x480
PC Windows, RTX 3070 Ti Laptop GPU

The Perspective view shows the printer's status, the zone state, a stop latch and System Start, Stop and Reset buttons. The latch that ran in the demo is the printerSite Gateway script. Details: demo site.

The Perspective view with the stop latched and the printer paused

The customer side of the demo is in demo_site/ and is not part of the product:

  • demo_site/printer_ignition/: the Perspective printer project, the local MQTT connector for the printer, and the stop and reset logic.
  • demo_site/pi_camera/: the camera service that runs on the Pi.

Not in this repo: the Ignition gateway itself, the connector's Windows service wrapper, and the printer's credentials. The app meets the demo site only through a camera address and its published tags.

Rules by prompt

Type Rule that was run Tested
Demo rule A hand and a water bottle are both in the area Yes
Presence A person is in the area Yes
Non-worker A person and a dog are both in the area, with a real dog Yes

Not yet validated:

  • Presence on a conveyor belt. No conveyor was used.
  • Authorization: red vest may enter, yellow vest stops the machine.
  • PPE: only people wearing a hard hat may be in the zone. The helmet-check skill gives an advisory answer in VlmState only.
  • Headcount: at most 2 people in the zone. A count zone publishes Count1 for the whole frame, and SCADA would compare the limit.
  • Non-worker: a child in view.

Test every rule change before going live. The app, the model version and the API still need normal maintenance.

Results

Owner-tested on November 4, 2026, through Ignition to a real printer. Observed by hand, not timed. Rule: person AND dog.

Scene State Printer
Person alone Clear Kept running
Person holding a real dog Active Stopped
Camera disabled Unknown Stopped

Check times seen by the owner in the running app so far: 2-4 s on average. Tests with more camera angles and prompts are still to be added.

There is no accuracy benchmark yet. Details are in the test results.

Quickstart

Docker needs an NVIDIA GPU with 8 GB or more, host networking turned on in Docker Desktop, and a Hugging Face token approved for facebook/sam3.1.

git clone https://github.com/celikender/vLock-AI-Vision.git
cd vLock-AI-Vision
cp .env.example .env
docker compose up -d --build

Set HF_TOKEN in .env before the last command. Then open http://localhost:5056 and create the admin account.

docker compose logs -f sam
docker compose restart sam
docker compose down

Without a GPU, use the native start on Windows with Python 3.12 and set VLOCK_SAM_BACKEND=meta_api. See the install guide. Docker was tested with the local GPU engine only. More in the Docker guide.

Variables in .env:

Variable Default Purpose
VLOCK_SAM_BACKEND local local (GPU worker), meta_api (one image per check) or meta_api_video (four-frame clip)
META_API_KEY Muse Spark and the Meta SAM engines
META_BASE_URL https://api.meta.ai/v1 Meta Model API address
META_SAM_MODEL sam-3.1 SAM model name
META_MUSE_MODEL muse-spark-1.3 Muse model name
VLOCK_SAM_TIMEOUT_MS 3000 Limit per Meta request
VLOCK_SAM_DAILY_LIMIT_USD 10 Estimated spend per UTC day at which paid requests stop
VLOCK_OPCUA_SERVER_USERNAME, VLOCK_OPCUA_SERVER_PASSWORD OPC UA login for SCADA on another PC. Password of 12 or more characters
VLOCK_API_TOKEN Optional bearer token for the REST API
HF_TOKEN Docker only: downloads the SAM 3.1 weights once

Set in the app, not in .env:

  • Camera: per zone. A Pi camera service at <Pi address>:8080 on a private network, or an rtsp:// address. RTSP has not been tested with a real camera.
  • OPC UA and MQTT: on the Integrations page. OPC UA defaults to port 4845. MQTT is off by default.

SCADA integration

The app is a read-only OPC UA server. In Ignition, add an OPC UA connection named vLock Bridge:

opc.tcp://127.0.0.1:4845/vlock/

The vLock Bridge connection in the Ignition Gateway

Each zone has the same tags at nsu=urn:vlock:bridge:v1;s=Bridge/Zones/<tag key>/<tag>.

Zone A-101 tags in the Ignition Designer Tag Browser, next to the Perspective view

Tag Type Meaning
State String Active, Clear, Unknown, or Valid for count zones
Active Boolean Rule met. Bad quality when Unknown
Quality String Good, Unknown or Stale
Reason String Why the zone has this state
Settled Boolean False while a fresh check disagrees with State and is being confirmed. Bad quality when Unknown
Count1, Count2 Int32 Detections of each object in the whole frame
ObservedAt, AgeSeconds String, Double Time and age of the analysed frame
Bridge/HeartbeatCounter, Bridge/Online Int64, Boolean App heartbeat

Read State, not only Active. Treat Unknown or Bad quality as stop. Accept a reset only while State is Clear and Settled is true: State changes after two matching checks, so for one check it can still read Clear after something has entered.

The same status over REST and MQTT:

GET http://localhost:5056/api/v1/zones
GET http://localhost:5056/api/v1/zones/<tag key>
MQTT topic: <topic prefix>/zones/<tag key>/state
{
  "schema_version": 1,
  "TagKey": "A-101",
  "State": "Clear",
  "Active": false,
  "Quality": "Good",
  "Settled": true,
  "Rule": "hand overlaps the area AND bottle overlaps the area for 1 s",
  "Object1": "hand",
  "Object2": "bottle",
  "Count1": 1,
  "Count2": 0
}

The example shows some of the fields. The tag package is ignition/vlock-zones.json, with the vLockZone UDT. Full list: zone tags. Setup steps: Ignition guide.

Scope and safety

  • The app publishes status only. It sends no machine commands.
  • Latch, reset and stop logic belong in SCADA. The demo ran the latch script in demo_site/printer_ignition/. ignition/stop_latch_example.py is a separate example that has not run in a real gateway.
  • It is not a certified safety device.
  • It does not replace interlocks, light curtains or lockout/tagout.
  • A check takes seconds, so this is not a fast stop.
  • One camera and one monitoring job at a time.
  • Accuracy has been sampled, not benchmarked.

Roadmap

  • On-demand camera check, run only when an interlock or light curtain is broken.
  • Debounce for Unknown in the app. Today the demo's latch script waits 2 s.
  • Log the active rule and prompt with each state change.
  • Test what is implemented but not yet run: RTSP cameras and the Muse frame-check skills.

Built for

The Meta Global AI Developer Hackathon 2026, Indie Developer Track, by Ender Celik. Gallery entry.

The stop latch idea comes from my earlier project, vLock Digital LOTO, an Ignition Perspective demonstration. No code was copied from it.

License

The code is licensed under Apache-2.0. The SAM 3.1 weights stay under Meta's own license, and each user requests access on Hugging Face.

About

Prompt-configured camera vision for SCADA. SAM 3.1 watches a drawn zone and publishes Clear, Active or Unknown over OPC UA, MQTT or REST.

Topics

Resources

Stars

0 stars

Watchers

0 watching

Forks

Contributors

Languages