Home Assistant integration that reads a CHINT DTSU666 / DTSU666-H three-phase
energy meter over Modbus TCP — directly or through an RS485-to-TCP gateway
(default Modbus port 502, slave/unit ID 4).
It exposes 28 sensors (voltages, currents, active/reactive/apparent power per phase and total, power factor, frequency, and import/export energy counters) ready for the Home Assistant Energy Dashboard.
The register map is not guessed: it was verified against a physical CHINT DTSU666 and cross-checked against
lmatula/ha_chint_pm,elfabriceu/DTSU666-Modbusand the CHINT manual.
- Copy
custom_components/dtsu666_meter/into your HAconfig/custom_components/(or add this repo as a HACS custom repository, category Integration). HACS custom repository URL:https://github.com/Developer089/ha-dtsu666-meter - Restart Home Assistant.
- Settings → Devices & Services → Add Integration → "DTSU666".
- Enter host / port / slave ID / polling interval. Connection is validated before the entry is created.
Defaults: port 502, slave ID 4, scan interval 1 s. The scan interval
accepts decimals and can go as low as 0.2 s (200 ms) (max 600 s); it can
be changed later via the integration's Configure (options) button.
Very low intervals only make sense over direct/fast Modbus TCP. Behind a 9600-baud RS485-to-TCP gateway one full read cycle (4 register blocks) takes longer than 200 ms, so the effective rate is capped by the link, not the setting — a too-aggressive interval just queues reads.
Copy yaml_package/dtsu666_modbus.yaml into config/packages/, enable packages
in configuration.yaml:
homeassistant:
packages: !include_dir_named packagesEdit host/port/slave at the top of the file and restart. Fewer features (no UI, no graceful per-block degradation) but zero custom code.
| Quantity | Address | Scale | Unit |
|---|---|---|---|
| Voltage L1-L2 / L2-L3 / L3-L1 | 0x2000 / 0x2002 / 0x2004 | ×0.1 | V |
| Voltage L1 / L2 / L3 | 0x2006 / 0x2008 / 0x200A | ×0.1 | V |
| Current L1 / L2 / L3 | 0x200C / 0x200E / 0x2010 | ×0.001 | A |
| Active power total / L1 / L2 / L3 | 0x2012 / 0x2014 / 0x2016 / 0x2018 | ×0.1 | W |
| Reactive power total / L1 / L2 / L3 | 0x201A / 0x201C / 0x201E / 0x2020 | ×0.1 | var |
| Apparent power total / L1 / L2 / L3 | 0x2022 / 0x2024 / 0x2026 / 0x2028 | ×0.1 | VA |
| Power factor total / L1 / L2 / L3 | 0x202A / 0x202C / 0x202E / 0x2030 | ×0.001 | – |
| Frequency | 0x2044 | ×0.01 | Hz |
| Energy imported | 0x401E | ×1 | kWh |
| Energy exported | 0x4028 | ×1 | kWh |
Negative Active power total = export to grid. The integration reads the map in
4 contiguous blocks per cycle; a single failing block degrades only its own
sensors instead of taking the whole device offline.
energy_import_total and energy_export_total are device_class: energy,
state_class: total_increasing, kWh — add them as Grid consumption and
Return to grid in Settings → Dashboards → Energy.
- Home Assistant 2024.12+ (uses
entry.runtime_data,OptionsFlowwithout passing the entry, modern typing). pymodbus3.9–3.11 — Home Assistant ships its own pinned version; the integration decodes FLOAT32 withstructso it does not depend on the pymodbus payload/converter API that changed across 3.9 → 3.11.
- Cannot connect: verify host/port and that the slave/unit ID matches the
meter (this integration defaults to
4; other installs commonly use1or11). Only one Modbus master can talk to the gateway at a time. - Nonsensical values: would indicate a word-order mismatch — this map is
big-endian word order, confirmed against the physical meter; no
swap. - Enable debug logging:
logger:
logs:
custom_components.dtsu666_meter: debugHome Assistant / HACS pull the integration icon from the central
home-assistant/brands repo, not
from this repository — so a generic placeholder is shown until a brand is
accepted there. See branding/README.md for the exact
image specs and the submission steps (and the note on using the CHINT
trademark). The mark in this README is an original placeholder, not the CHINT
logo.