Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathWeb.py
More file actions
506 lines (473 loc) · 22.6 KB
/
Copy pathWeb.py
File metadata and controls
506 lines (473 loc) · 22.6 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
import streamlit as st
import streamlit_authenticator as stauth
import yaml
import json
import sqlite3
import time
from opcua import Client
OpcServerUrl = "opc.tcp://localhost:48020"
def ConnectToOpcServer():
OpcClient = Client(OpcServerUrl)
try:
OpcClient.connect()
print("Successfully connected to OPC UA server")
return OpcClient
except Exception as e:
print(f"Connection failed: {e}")
return None
def InitDatabase():
Connection = sqlite3.connect('heating_data.db')
Cursor = Connection.cursor()
Cursor.execute('''CREATE TABLE IF NOT EXISTS HeatingData
(Id INTEGER PRIMARY KEY AUTOINCREMENT,
Name TEXT UNIQUE,
Time INTEGER,
Power INTEGER,
Voltage INTEGER,
Current INTEGER,
Frequency INTEGER,
Mode TEXT,
CoolingActive BOOLEAN,
PreHeatingActive BOOLEAN)''')
Connection.commit()
Cursor.execute("PRAGMA table_info(HeatingData)")
columns = Cursor.fetchall()
column_names = [column[1] for column in columns]
required_columns = ['Name', 'Time', 'Power', 'Voltage', 'Current', 'Frequency', 'Mode', 'CoolingActive', 'PreHeatingActive']
for col in required_columns:
if col not in column_names:
try:
if col in ['CoolingActive', 'PreHeatingActive']:
Cursor.execute(f'ALTER TABLE HeatingData ADD COLUMN {col} BOOLEAN')
else:
Cursor.execute(f'ALTER TABLE HeatingData ADD COLUMN {col} INTEGER')
Connection.commit()
print(f"Added missing column: {col}")
except sqlite3.OperationalError as e:
print(f"Error adding column {col}: {e}")
print(f"Database columns: {column_names}")
Connection.close()
Connection = sqlite3.connect('heating_data.db')
Cursor = Connection.cursor()
Cursor.execute("PRAGMA table_info(HeatingData)")
columns = Cursor.fetchall()
column_names = [column[1] for column in columns]
if 'Mode' not in column_names:
Cursor.execute('ALTER TABLE HeatingData ADD COLUMN Mode TEXT')
Connection.commit()
print("Added missing Mode column to database")
print(f"Database columns: {column_names}")
Connection.close()
def GetSavedConfigurations(mode):
Connection = sqlite3.connect('heating_data.db')
Cursor = Connection.cursor()
try:
if mode == "Simple":
Cursor.execute('''SELECT Name, Time, Power, CoolingActive, PreHeatingActive FROM HeatingData WHERE Mode = ?''', (mode,))
else:
Cursor.execute('''SELECT Name, Time, Voltage, Current, Frequency, CoolingActive, PreHeatingActive FROM HeatingData WHERE Mode = ?''', (mode,))
Configurations = Cursor.fetchall()
except sqlite3.OperationalError as e:
print(f"Database error: {e}")
Configurations = []
Connection.close()
return Configurations
def DeleteConfiguration(Name):
try:
Connection = sqlite3.connect('heating_data.db')
Cursor = Connection.cursor()
Cursor.execute('DELETE FROM HeatingData WHERE Name = ?', (Name,))
Connection.commit()
return True
except Exception as e:
print(f"Error deleting configuration: {e}")
return False
finally:
Connection.close()
def SaveConfiguration(Name):
try:
Connection = sqlite3.connect('heating_data.db')
Cursor = Connection.cursor()
Time = st.session_state.get("TimeInput", 0)
Mode = st.session_state.CurrentMode
CoolingActive = st.session_state.get("CoolingActive", False)
PreHeatingActive = st.session_state.get("PreHeatingActive", False)
if Mode == "Simple":
Power = st.session_state.get("PowerInput", 0)
Cursor.execute('''INSERT OR REPLACE INTO HeatingData
(Name, Time, Power, Mode, CoolingActive, PreHeatingActive)
VALUES (?, ?, ?, ?, ?, ?)''',
(Name, Time, Power, Mode, CoolingActive, PreHeatingActive))
else:
Voltage = st.session_state.get("VoltageInput", 0)
Current = st.session_state.get("CurrentInput", 0)
Frequency = st.session_state.get("FrequencyInput", 0)
Cursor.execute('''INSERT OR REPLACE INTO HeatingData
(Name, Time, Voltage, Current, Frequency, Mode, CoolingActive, PreHeatingActive)
VALUES (?, ?, ?, ?, ?, ?, ?, ?)''',
(Name, Time, Voltage, Current, Frequency, Mode, CoolingActive, PreHeatingActive))
Connection.commit()
return True
except Exception as e:
print(f"Error saving configuration: {e}")
return False
finally:
Connection.close()
def HandleStartButton():
st.session_state["Status"] = "Running"
st.session_state["ResultantPower"] = 0
st.session_state["HeatingTemperature"] = 0
Data = {
"Time": st.session_state.TimeInput,
"Status": "Running",
"CoolingActive": st.session_state.CoolingActive,
"PreHeatingActive": st.session_state.PreHeatingActive
}
opcua_client = ConnectToOpcServer()
if st.session_state.CurrentMode == "Simple":
Data["Power"] = st.session_state.PowerInput
if opcua_client:
try:
# Simple Mode Node IDs - Replace with your actual node IDs
time_node = opcua_client.get_node("ns=2;s=SimpleMode.Time")
power_node = opcua_client.get_node("ns=2;s=SimpleMode.Power")
status_node = opcua_client.get_node("ns=2;s=SimpleMode.Status")
cooling_node = opcua_client.get_node("ns=2;s=SimpleMode.CoolingActive")
preheating_node = opcua_client.get_node("ns=2;s=SimpleMode.PreHeatingActive")
# Write values to OPC UA server
time_node.set_value(st.session_state.TimeInput)
power_node.set_value(st.session_state.PowerInput)
status_node.set_value("Running")
cooling_node.set_value(st.session_state.CoolingActive)
preheating_node.set_value(st.session_state.PreHeatingActive)
print("Simple mode data sent to OPC UA server")
except Exception as e:
print(f"Error writing to OPC UA server: {e}")
finally:
opcua_client.disconnect()
else:
Data.update({
"Voltage": st.session_state.VoltageInput,
"Current": st.session_state.CurrentInput,
"Frequency": st.session_state.FrequencyInput
})
if opcua_client:
try:
# Advanced Mode Node IDs - Replace with your actual node IDs
time_node = opcua_client.get_node("ns=2;s=AdvancedMode.Time")
voltage_node = opcua_client.get_node("ns=2;s=AdvancedMode.Voltage")
current_node = opcua_client.get_node("ns=2;s=AdvancedMode.Current")
frequency_node = opcua_client.get_node("ns=2;s=AdvancedMode.Frequency")
status_node = opcua_client.get_node("ns=2;s=AdvancedMode.Status")
cooling_node = opcua_client.get_node("ns=2;s=AdvancedMode.CoolingActive")
preheating_node = opcua_client.get_node("ns=2;s=AdvancedMode.PreHeatingActive")
# Write values to OPC UA server
time_node.set_value(st.session_state.TimeInput)
voltage_node.set_value(st.session_state.VoltageInput)
current_node.set_value(st.session_state.CurrentInput)
frequency_node.set_value(st.session_state.FrequencyInput)
status_node.set_value("Running")
cooling_node.set_value(st.session_state.CoolingActive)
preheating_node.set_value(st.session_state.PreHeatingActive)
print("Advanced mode data sent to OPC UA server")
except Exception as e:
print(f"Error writing to OPC UA server: {e}")
finally:
opcua_client.disconnect()
with open("heating_data.json", "w") as JsonFile:
json.dump(Data, JsonFile, indent=4)
def HandleStopButton():
st.session_state["Status"] = "Stopped"
Data = {
"Time": st.session_state.TimeInput,
"Status": "Stopped",
"CoolingActive": st.session_state.CoolingActive,
"PreHeatingActive": st.session_state.PreHeatingActive
}
opcua_client = ConnectToOpcServer()
if st.session_state.CurrentMode == "Simple":
Data["Power"] = st.session_state.PowerInput
if opcua_client:
try:
# Simple Mode Node IDs - Replace with your actual node IDs
status_node = opcua_client.get_node("ns=2;s=SimpleMode.Status")
cooling_node = opcua_client.get_node("ns=2;s=SimpleMode.CoolingActive")
preheating_node = opcua_client.get_node("ns=2;s=SimpleMode.PreHeatingActive")
# Write values to OPC UA server
status_node.set_value("Stopped")
cooling_node.set_value(st.session_state.CoolingActive)
preheating_node.set_value(st.session_state.PreHeatingActive)
print("Simple mode stop command sent to OPC UA server")
except Exception as e:
print(f"Error writing to OPC UA server: {e}")
finally:
opcua_client.disconnect()
else:
Data.update({
"Voltage": st.session_state.VoltageInput,
"Current": st.session_state.CurrentInput,
"Frequency": st.session_state.FrequencyInput
})
if opcua_client:
try:
# Advanced Mode Node IDs - Replace with your actual node IDs
status_node = opcua_client.get_node("ns=2;s=AdvancedMode.Status")
cooling_node = opcua_client.get_node("ns=2;s=AdvancedMode.CoolingActive")
preheating_node = opcua_client.get_node("ns=2;s=AdvancedMode.PreHeatingActive")
# Write values to OPC UA server
status_node.set_value("Stopped")
cooling_node.set_value(st.session_state.CoolingActive)
preheating_node.set_value(st.session_state.PreHeatingActive)
print("Advanced mode stop command sent to OPC UA server")
except Exception as e:
print(f"Error writing to OPC UA server: {e}")
finally:
opcua_client.disconnect()
with open("heating_data.json", "w") as JsonFile:
json.dump(Data, JsonFile, indent=4)
def RenderSidebar():
with st.sidebar:
st.write(f'Welcome *{st.session_state["name"]}*')
previous_mode = st.session_state.get("CurrentMode", "Simple")
new_mode = st.radio("System Mode", ["Simple", "Advanced"],index=0 if previous_mode == "Simple" else 1)
if new_mode != previous_mode:
st.session_state.CoolingActive = False
st.session_state.PreHeatingActive = False
if new_mode == "Simple":
st.session_state.PowerInput = 0
else:
st.session_state.VoltageInput = 0
st.session_state.CurrentInput = 0
st.session_state.FrequencyInput = 0
# Reset time input
st.session_state.TimeInput = 0
st.session_state.CurrentMode = new_mode
Configurations = GetSavedConfigurations(st.session_state.CurrentMode)
CurrentConfigNames = [conf[0] for conf in Configurations]
config_col, delete_col = st.columns([3, 1])
with config_col:
SelectedConfig = st.selectbox("Saved Configurations", ["Select Configuration"] + CurrentConfigNames,key="ConfigSelector")
with delete_col:
st.write("Delete")
if st.button("🗑️", key="DeleteButton"):
if SelectedConfig != "Select Configuration":
DeleteConfiguration(SelectedConfig)
st.rerun()
Authenticator.logout()
return SelectedConfig
def RenderMainControls():
st.header("Heating Control")
toggle_col1, toggle_col2, toggle_col3 = st.columns(3)
with toggle_col1:
is_active = st.toggle("System Active", key="HeatingToggle")
with toggle_col2:
cooling_active = st.toggle("Cooling Active", key="CoolingToggle")
with toggle_col3:
preheating_active = st.toggle("Pre-Heating Active", key="PreHeatingToggle")
st.session_state.CoolingActive = cooling_active
st.session_state.PreHeatingActive = preheating_active
if not is_active:
st.warning("System is inactive. Activate to enter data.")
# Return dummy values or None when system is inactive
if st.session_state.CurrentMode == "Simple":
return 0, 0
else:
return 0, 0, 0, 0
if st.session_state.CurrentMode == "Simple":
Left, Right = st.columns(2)
Time = Left.number_input("Time (s)", min_value=0, max_value=1000, step=5, key="TimeInput", value=st.session_state.InitialTime)
Power = Right.number_input("Power (P)", min_value=0, max_value=1000, step=20, key="PowerInput", value=st.session_state.InitialPower)
return Time, Power
else:
cols = st.columns(4)
Time = cols[0].number_input("Time (s)", min_value=0, max_value=1000, step=5, key="TimeInput", value=st.session_state.InitialTime)
Voltage = cols[1].number_input("Voltage (V)", min_value=0, max_value=480, step=10, key="VoltageInput", value=st.session_state.InitialVoltage)
Current = cols[2].number_input("Current (A)", min_value=0, max_value=100, step=1, key="CurrentInput", value=st.session_state.InitialCurrent)
Frequency = cols[3].number_input("Freq (Hz)", min_value=0, max_value=60, step=1, key="FrequencyInput", value=st.session_state.InitialFrequency)
return Time, Voltage, Current, Frequency
def RenderControlButtons():
is_active = st.session_state.get("HeatingToggle", False)
Left, Middle, Right = st.columns(3)
with Left:
if is_active and st.button("Start", use_container_width=True):
HandleStartButton()
with Middle:
if is_active and st.button("Stop", use_container_width=True):
HandleStopButton()
return Right
def RenderSaveConfiguration(RightCol):
is_active = st.session_state.get("HeatingToggle", False)
if not is_active:
return
with RightCol:
with st.popover("Save Configuration", use_container_width=True):
st.markdown("### Enter Configuration Name")
save_name = st.text_input("Name:", key="save_name_input")
save_button = st.button("Save", key="save_button")
if save_button and save_name:
existing_configs = GetSavedConfigurations(st.session_state.CurrentMode)
existing_names = [config[0] for config in existing_configs]
if save_name not in existing_names:
if SaveConfiguration(save_name):
st.success(f"Configuration saved as: **{save_name}**")
st.rerun()
else:
st.error("Failed to save configuration")
else:
st.error("Configuration name already exists!")
def PollOpcData():
opcua_client = ConnectToOpcServer()
if opcua_client:
try:
# Replace these node IDs with your actual OPC UA node IDs
CurrentConsumptionNode = opcua_client.get_node("ns=2;s=System.CurrentConsumption")
TemperatureNode = opcua_client.get_node("ns=2;s=System.Temperature")
CoolingTemperatureNode = opcua_client.get_node("ns=2;s=System.CoolingTemperature")
CoolingPressureNode = opcua_client.get_node("ns=2;s=System.CoolingPressure")
AdditionalParameter1Node = opcua_client.get_node("ns=2;s=System.AdditionalParameter1")
AdditionalParameter2Node = opcua_client.get_node("ns=2;s=System.AdditionalParameter2")
current_consumption = CurrentConsumptionNode.get_value() if CurrentConsumptionNode else 0
temperature = TemperatureNode.get_value() if TemperatureNode else 0
cooling_temperature = CoolingTemperatureNode.get_value() if CoolingTemperatureNode else 0
cooling_pressure = CoolingPressureNode.get_value() if CoolingPressureNode else 0
additional_parameter1 = AdditionalParameter1Node.get_value() if AdditionalParameter1Node else 0
additional_parameter2 = AdditionalParameter2Node.get_value() if AdditionalParameter2Node else 0
return {
"CurrentConsumption": current_consumption,
"Temperature": temperature,
"CoolingTemperature": cooling_temperature,
"CoolingPressure": cooling_pressure,
"AdditionalParameter1": additional_parameter1,
"AdditionalParameter2": additional_parameter2
}
except Exception as e:
print(f"Error reading from OPC UA server: {e}")
return None
finally:
opcua_client.disconnect()
return None
def RenderFeedbackParameters():
st.header("System Parameters")
# Poll data every second
data = PollOpcData()
if data:
cols = st.columns(4)
cols[0].metric("Status", st.session_state.get("Status", "Idle"))
cols[1].metric("Current Consumption", f"{data.get('CurrentConsumption', 0)} A")
cols[2].metric("Temperature", f"{data.get('Temperature', 0)}°C")
cols[3].metric("Cooling Temperature", f"{data.get('CoolingTemperature', 0)}°C")
st.subheader("Automatic Parameters")
auto_cols = st.columns(3)
auto_cols[0].metric("Cooling Pressure", f"{data.get('CoolingPressure', 0)} bar")
auto_cols[1].metric("Additional Automatic Parameter 1", f"{data.get('AdditionalParameter1', 0)}")
auto_cols[2].metric("Additional Automatic Parameter 2", f"{data.get('AdditionalParameter2', 0)}")
else:
cols = st.columns(4)
cols[0].metric("Status", st.session_state.get("Status", "Idle"))
cols[1].metric("Current Consumption", "0 A")
cols[2].metric("Temperature", "0°C")
cols[3].metric("Cooling Temperature", "0°C")
st.subheader("Automatic Parameters")
auto_cols = st.columns(3)
auto_cols[0].metric("Cooling Pressure", "0 bar")
auto_cols[1].metric("Additional Automatic Parameter 1", "0")
auto_cols[2].metric("Additional Automatic Parameter 2", "0")
if 'InitialTime' not in st.session_state:
st.session_state.InitialTime = 0
if 'InitialPower' not in st.session_state:
st.session_state.InitialPower = 0
if 'InitialVoltage' not in st.session_state:
st.session_state.InitialVoltage = 0
if 'InitialCurrent' not in st.session_state:
st.session_state.InitialCurrent = 0
if 'InitialFrequency' not in st.session_state:
st.session_state.InitialFrequency = 0
if 'CurrentMode' not in st.session_state:
st.session_state.CurrentMode = "Simple"
if 'Status' not in st.session_state:
st.session_state.Status = "Idle"
if 'ResultantPower' not in st.session_state:
st.session_state.ResultantPower = 0
if 'HeatingTemperature' not in st.session_state:
st.session_state.HeatingTemperature = 0
if 'CoolingActive' not in st.session_state:
st.session_state.CoolingActive = False
if 'PreHeatingActive' not in st.session_state:
st.session_state.PreHeatingActive = False
if 'PowerInput' not in st.session_state:
st.session_state.PowerInput = 0
if 'VoltageInput' not in st.session_state:
st.session_state.VoltageInput = 0
if 'CurrentInput' not in st.session_state:
st.session_state.CurrentInput = 0
if 'FrequencyInput' not in st.session_state:
st.session_state.FrequencyInput = 0
if 'TimeInput' not in st.session_state:
st.session_state.TimeInput = 0
InitDatabase()
with open('access.yaml') as File:
Config = yaml.safe_load(File)
Authenticator = stauth.Authenticate(
Config['credentials'],
Config['cookie']['name'],
Config['cookie']['key'],
Config['cookie']['expiry_days']
)
try:
Authenticator.login()
except Exception as e:
st.error(e)
if st.session_state.get('authentication_status'):
if "last_poll_time" not in st.session_state:
st.session_state.last_poll_time = 0
if "opc_data" not in st.session_state:
st.session_state.opc_data = {}
# Set polling interval (in seconds)
polling_interval = 1 # Poll every 1 second
current_time = time.time()
if current_time - st.session_state.last_poll_time >= polling_interval:
data = PollOpcData()
if data:
st.session_state.opc_data = data
st.session_state.last_poll_time = current_time
SelectedConfig = RenderSidebar()
if SelectedConfig != "Select Configuration":
try:
Connection = sqlite3.connect('heating_data.db')
Cursor = Connection.cursor()
Cursor.execute('''SELECT Id, Name, Time, Power, Voltage, Current, Frequency, Mode, CoolingActive, PreHeatingActive
FROM HeatingData
WHERE Name = ?''', (SelectedConfig,))
config = Cursor.fetchone()
Connection.close()
if config:
st.session_state.InitialTime = config[2]
if config[7] == "Simple":
st.session_state.InitialPower = config[3]
st.session_state.CoolingActive = config[8]
st.session_state.PreHeatingActive = config[9]
else:
st.session_state.InitialVoltage = config[4]
st.session_state.InitialCurrent = config[5]
st.session_state.InitialFrequency = config[6]
st.session_state.CoolingActive = config[8]
st.session_state.PreHeatingActive = config[9]
else:
st.error("Selected configuration not found in database")
except IndexError:
st.error("Configuration data format incorrect. Please check database integrity.")
except Exception as e:
st.error(f"Error loading configuration: {str(e)}")
if st.session_state.CurrentMode == "Simple":
Time, Power = RenderMainControls()
else:
Time, Voltage, Current, Frequency = RenderMainControls()
RightCol = RenderControlButtons()
RenderSaveConfiguration(RightCol)
RenderFeedbackParameters()
elif st.session_state.get('authentication_status') is False:
st.error("Username/password is incorrect")
elif st.session_state.get('authentication_status') is None:
st.warning("Please enter your username and password")
# TUclausthal logo
st.logo(image="Images/TUC_logo.png", size="large", icon_image=None)