Basit Mustafa e62338d3a0 fix(queue): drain correct session queue after cross-session stream completion (#964)
When a session finishes streaming while the user has switched to a different
session, setBusy(false) was draining S.session.session_id (the currently
*viewed* session) instead of the session that actually finished. Queued
follow-up messages were silently dropped.

Root cause: setBusy() has no context about which session triggered it.
The activeSid closure variable inside attachLiveStream() knew the right
session but was not propagated.

Fix: add _queueDrainSid module global (null by default). Stream done and
error handlers set it to activeSid immediately before calling setBusy(false).
setBusy(false) reads and clears _queueDrainSid, falling back to S.session if
it is unset (the common case where the user hasn't switched away).

Handlers patched: done event, start-call error handler, stream_end/stream_stop
reconnection fallback, and max-retry error exit.