diff --git a/deploy/runtime/defaults/CustomGeneration PVWatts Wind FuelCell Battery Hybrid_Single Owner.json b/deploy/runtime/defaults/CustomGeneration PVWatts Wind FuelCell Battery Hybrid_Single Owner.json index 31a6946de3..664f4a1128 100644 --- a/deploy/runtime/defaults/CustomGeneration PVWatts Wind FuelCell Battery Hybrid_Single Owner.json +++ b/deploy/runtime/defaults/CustomGeneration PVWatts Wind FuelCell Battery Hybrid_Single Owner.json @@ -203,7 +203,7 @@ "losses": 14.075660688264469, "losses_user": 14.0, "module_costunits": 0.0, - "module_is_bifacial": 1.0, + "module_is_bifacial": 0.0, "module_num_units": 1.0, "module_power": 100000.0, "module_total": 34000000.0, diff --git a/deploy/runtime/defaults/PVWatts Battery_All Equity Partnership Flip.json b/deploy/runtime/defaults/PVWatts Battery_All Equity Partnership Flip.json index 5babc1d128..39d7a4fb0d 100644 --- a/deploy/runtime/defaults/PVWatts Battery_All Equity Partnership Flip.json +++ b/deploy/runtime/defaults/PVWatts Battery_All Equity Partnership Flip.json @@ -29861,7 +29861,7 @@ "mera_name2": "Replacement Reserve 2", "mera_name3": "Replacement Reserve 3", "module_costunits": 0.0, - "module_is_bifacial": 1.0, + "module_is_bifacial": 0.0, "module_num_units": 1.0, "module_power": 100000.0, "module_total": 34000000.0, diff --git a/deploy/runtime/defaults/PVWatts Battery_Leveraged Partnership Flip.json b/deploy/runtime/defaults/PVWatts Battery_Leveraged Partnership Flip.json index f5ce28e476..f7dc40ced8 100644 --- a/deploy/runtime/defaults/PVWatts Battery_Leveraged Partnership Flip.json +++ b/deploy/runtime/defaults/PVWatts Battery_Leveraged Partnership Flip.json @@ -29870,7 +29870,7 @@ "mera_name2": "Replacement Reserve 2", "mera_name3": "Replacement Reserve 3", "module_costunits": 0.0, - "module_is_bifacial": 1.0, + "module_is_bifacial": 0.0, "module_num_units": 1.0, "module_power": 100000.0, "module_total": 34000000.0, diff --git a/deploy/runtime/defaults/PVWatts Battery_Merchant Plant.json b/deploy/runtime/defaults/PVWatts Battery_Merchant Plant.json index ed719a9f78..ea7a304c5a 100644 --- a/deploy/runtime/defaults/PVWatts Battery_Merchant Plant.json +++ b/deploy/runtime/defaults/PVWatts Battery_Merchant Plant.json @@ -19361,7 +19361,7 @@ "mera_name2": "Replacement Reserve 2", "mera_name3": "Replacement Reserve 3", "module_costunits": 0.0, - "module_is_bifacial": 1.0, + "module_is_bifacial": 0.0, "module_num_units": 1.0, "module_power": 100000.0, "module_total": 34000000.0, diff --git a/deploy/runtime/defaults/PVWatts Battery_Sale Leaseback.json b/deploy/runtime/defaults/PVWatts Battery_Sale Leaseback.json index 1d12cb6d42..e348d02ab4 100644 --- a/deploy/runtime/defaults/PVWatts Battery_Sale Leaseback.json +++ b/deploy/runtime/defaults/PVWatts Battery_Sale Leaseback.json @@ -29856,7 +29856,7 @@ "mera_name2": "Replacement Reserve 2", "mera_name3": "Replacement Reserve 3", "module_costunits": 0.0, - "module_is_bifacial": 1.0, + "module_is_bifacial": 0.0, "module_num_units": 1.0, "module_power": 100000.0, "module_total": 34000000.0, diff --git a/deploy/runtime/defaults/PVWatts Battery_Single Owner.json b/deploy/runtime/defaults/PVWatts Battery_Single Owner.json index 757cc96592..197114f7f7 100644 --- a/deploy/runtime/defaults/PVWatts Battery_Single Owner.json +++ b/deploy/runtime/defaults/PVWatts Battery_Single Owner.json @@ -29881,7 +29881,7 @@ "mera_name2": "Replacement Reserve 2", "mera_name3": "Replacement Reserve 3", "module_costunits": 0.0, - "module_is_bifacial": 1.0, + "module_is_bifacial": 0.0, "module_num_units": 1.0, "module_power": 100000.0, "module_total": 34000000.0, diff --git a/deploy/runtime/defaults/PVWatts Wind Battery Hybrid_Single Owner.json b/deploy/runtime/defaults/PVWatts Wind Battery Hybrid_Single Owner.json index 51d4e1a2a9..8727701f7c 100644 --- a/deploy/runtime/defaults/PVWatts Wind Battery Hybrid_Single Owner.json +++ b/deploy/runtime/defaults/PVWatts Wind Battery Hybrid_Single Owner.json @@ -121,7 +121,7 @@ "losses": 14.075660688264469, "losses_user": 14.0, "module_costunits": 0.0, - "module_is_bifacial": 1.0, + "module_is_bifacial": 0.0, "module_num_units": 1.0, "module_power": 100000.0, "module_total": 34000000.0, diff --git a/deploy/runtime/defaults/PVWatts Wind FuelCell Battery Hybrid_Single Owner.json b/deploy/runtime/defaults/PVWatts Wind FuelCell Battery Hybrid_Single Owner.json index 5bd0cc3caa..4e113ed0be 100644 --- a/deploy/runtime/defaults/PVWatts Wind FuelCell Battery Hybrid_Single Owner.json +++ b/deploy/runtime/defaults/PVWatts Wind FuelCell Battery Hybrid_Single Owner.json @@ -121,7 +121,7 @@ "losses": 14.075660688264469, "losses_user": 14.0, "module_costunits": 0.0, - "module_is_bifacial": 1.0, + "module_is_bifacial": 0.0, "module_num_units": 1.0, "module_power": 100000.0, "module_total": 34000000.0, diff --git a/deploy/runtime/defaults/PVWatts_All Equity Partnership Flip.json b/deploy/runtime/defaults/PVWatts_All Equity Partnership Flip.json index abf28e9c13..920f8768a6 100644 --- a/deploy/runtime/defaults/PVWatts_All Equity Partnership Flip.json +++ b/deploy/runtime/defaults/PVWatts_All Equity Partnership Flip.json @@ -19240,7 +19240,7 @@ "mera_name2": "Replacement Reserve 2", "mera_name3": "Replacement Reserve 3", "module_costunits": 0.0, - "module_is_bifacial": 1.0, + "module_is_bifacial": 0.0, "module_num_units": 1.0, "module_power": 100000.0, "module_total": 34000000.0, diff --git a/deploy/runtime/defaults/PVWatts_Community Solar.json b/deploy/runtime/defaults/PVWatts_Community Solar.json index c67c459033..4ff291bb0e 100644 --- a/deploy/runtime/defaults/PVWatts_Community Solar.json +++ b/deploy/runtime/defaults/PVWatts_Community Solar.json @@ -9210,7 +9210,7 @@ "mera_name2": "Replacement Reserve 2", "mera_name3": "Replacement Reserve 3", "module_costunits": 0.0, - "module_is_bifacial": 1.0, + "module_is_bifacial": 0.0, "module_num_units": 1.0, "module_power": 3000.0, "module_total": 1020000.0000000001, diff --git a/deploy/runtime/defaults/PVWatts_LCOE Calculator.json b/deploy/runtime/defaults/PVWatts_LCOE Calculator.json index 2aefbea0e7..e00d64b375 100644 --- a/deploy/runtime/defaults/PVWatts_LCOE Calculator.json +++ b/deploy/runtime/defaults/PVWatts_LCOE Calculator.json @@ -8859,7 +8859,7 @@ "loss_wiring": 2.0, "losses": 14.075660688264469, "losses_user": 14.0, - "module_is_bifacial": 1.0, + "module_is_bifacial": 0.0, "module_type": 0.0, "pv_land_area_is_shown": 0.0, "pvwatts.advanced.is_shown": 0.0, diff --git a/deploy/runtime/defaults/PVWatts_Leveraged Partnership Flip.json b/deploy/runtime/defaults/PVWatts_Leveraged Partnership Flip.json index 4f4df985c4..f4bb660112 100644 --- a/deploy/runtime/defaults/PVWatts_Leveraged Partnership Flip.json +++ b/deploy/runtime/defaults/PVWatts_Leveraged Partnership Flip.json @@ -19249,7 +19249,7 @@ "mera_name2": "Replacement Reserve 2", "mera_name3": "Replacement Reserve 3", "module_costunits": 0.0, - "module_is_bifacial": 1.0, + "module_is_bifacial": 0.0, "module_num_units": 1.0, "module_power": 100000.0, "module_total": 34000000.0, diff --git a/deploy/runtime/defaults/PVWatts_Merchant Plant.json b/deploy/runtime/defaults/PVWatts_Merchant Plant.json index b49756adc7..27a096825c 100644 --- a/deploy/runtime/defaults/PVWatts_Merchant Plant.json +++ b/deploy/runtime/defaults/PVWatts_Merchant Plant.json @@ -9218,7 +9218,7 @@ "mera_name2": "Replacement Reserve 2", "mera_name3": "Replacement Reserve 3", "module_costunits": 0.0, - "module_is_bifacial": 1.0, + "module_is_bifacial": 0.0, "module_num_units": 1.0, "module_power": 100000.0, "module_total": 34000000.0, diff --git a/deploy/runtime/defaults/PVWatts_Sale Leaseback.json b/deploy/runtime/defaults/PVWatts_Sale Leaseback.json index aa88895113..70d005f629 100644 --- a/deploy/runtime/defaults/PVWatts_Sale Leaseback.json +++ b/deploy/runtime/defaults/PVWatts_Sale Leaseback.json @@ -19235,7 +19235,7 @@ "mera_name2": "Replacement Reserve 2", "mera_name3": "Replacement Reserve 3", "module_costunits": 0.0, - "module_is_bifacial": 1.0, + "module_is_bifacial": 0.0, "module_num_units": 1.0, "module_power": 100000.0, "module_total": 34000000.0, diff --git a/deploy/runtime/defaults/PVWatts_Single Owner.json b/deploy/runtime/defaults/PVWatts_Single Owner.json index 0b2c870383..d45787939b 100644 --- a/deploy/runtime/defaults/PVWatts_Single Owner.json +++ b/deploy/runtime/defaults/PVWatts_Single Owner.json @@ -19260,7 +19260,7 @@ "mera_name2": "Replacement Reserve 2", "mera_name3": "Replacement Reserve 3", "module_costunits": 0.0, - "module_is_bifacial": 1.0, + "module_is_bifacial": 0.0, "module_num_units": 1.0, "module_power": 100000.0, "module_total": 34000000.0, diff --git a/deploy/runtime/ui/Battery Dispatch Common.json b/deploy/runtime/ui/Battery Dispatch Common.json index 33cb860000..9197e8f344 100644 --- a/deploy/runtime/ui/Battery Dispatch Common.json +++ b/deploy/runtime/ui/Battery Dispatch Common.json @@ -689,12 +689,12 @@ "{", "\tlogmsg('Forecast data: ' + data);", "", - "\tforecast_run = ssc_module_create_from_case('generic_system');", + "\tforecast_run = ssc_module_create_from_case('custom_generation');", "\tssc_var(forecast_run, 'en_batt', false);", "\tssc_var(forecast_run, 'energy_output_array', data);", "\tssc_var(forecast_run, 'spec_mode', 1);", "", - "\tstatus = ssc_exec(forecast_run, 'generic_system', {'show_dialog'=true, 'hold_dialog'=true});", + "\tstatus = ssc_exec(forecast_run, 'custom_generation', {'show_dialog'=true, 'hold_dialog'=true});", "\t", "\tif (status != 0)", "\t{", diff --git a/doc/source/reference/configure_proxy_server.rst b/doc/source/reference/configure_proxy_server.rst index 27cfc7bb63..88fb715254 100644 --- a/doc/source/reference/configure_proxy_server.rst +++ b/doc/source/reference/configure_proxy_server.rst @@ -26,7 +26,7 @@ The following is a list of all of the URLs that SAM may use. You can find this l https://developer.nlr.gov/api/nsrdb/v2/solar/nsrdb-data-query.json?&api_key=&email=&wkt=POINT(%20) https://developer.nlr.gov/api/sam/v1/tracker https://sam.nlr.gov/sites/default/files/content/updates/messages.html - https://samrepo.nrelcloud.org/updates/welcome.lk + https://samrepo.nlr.gov/updates/welcome.lk https://nrel.github.io/SAM/doc/releasenotes.html https://developer.nlr.gov/api/reopt/stable/job//results/?api_key= https://developer.nlr.gov/api/reopt/stable/job?format=json&api_key= diff --git a/samples/Python Scripts/End Use Load Profiles/eulp/requirements.txt b/samples/Python Scripts/End Use Load Profiles/eulp/requirements.txt index 0fd6a0e8ec..9bc08ec3d7 100644 --- a/samples/Python Scripts/End Use Load Profiles/eulp/requirements.txt +++ b/samples/Python Scripts/End Use Load Profiles/eulp/requirements.txt @@ -3,4 +3,4 @@ matplotlib==3.6.0 pandas==1.5.2 pyarrow==14.0.1 seaborn==0.12.1 -urllib3==1.26.18 +urllib3==1.26.19 diff --git a/test_results_win64.csv b/test_results_win64.csv index e356bbffa1..359fe94123 100644 --- a/test_results_win64.csv +++ b/test_results_win64.csv @@ -14,13 +14,13 @@ PVWatts,Residential,13916.2,16.2152,NA,; PVWatts,Commercial,939340,6.02871,NA,; PVWatts,Third Party,11132.9,NA,NA,; PVWatts,Host Developer,939340,11.6977,12.505,; -PVWatts,Single Owner,219755184,6.07817,4.32275,; Warning: NPV is $-3.62613e+07. A negative NPV indicates project costs are higher than revenues. -PVWatts,Community Solar,6592818,7.55727,NA,; Warning: IRR at end of analysis period is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: IRR in target year is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: NPV is $-2.53329e+06. A negative NPV indicates project costs are higher than revenues. -PVWatts,Merchant Plant,219755184,5.84474,NA,; Warning: NPV is $-7.65915e+07. A negative NPV indicates project costs are higher than revenues. -PVWatts,Leveraged Partnership Flip,219755184,6.21232,4.32275,; Warning: IRR at end of analysis period is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: IRR in target year is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: NPV is $-3.82519e+07. A negative NPV indicates project costs are higher than revenues. -PVWatts,All Equity Partnership Flip,219755184,6.64701,4.32275,; Warning: IRR at end of analysis period is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: IRR in target year is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: NPV is $-1.53372e+07. A negative NPV indicates project costs are higher than revenues. Warning: NPV is $-3.01305e+07. A negative NPV indicates project costs are higher than revenues. -PVWatts,Sale Leaseback,219755184,7.31873,4.32275,; Warning: IRR at end of analysis period is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: NPV is $-6.2084e+07. A negative NPV indicates project costs are higher than revenues. -PVWatts,LCOE Calculator,219755184,NA,NA,; +PVWatts,Single Owner,211972144,6.28832,4.32264,; Warning: NPV is $-3.91364e+07. A negative NPV indicates project costs are higher than revenues. +PVWatts,Community Solar,6359332,7.82684,NA,; Warning: IRR at end of analysis period is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: IRR in target year is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: NPV is $-2.55635e+06. A negative NPV indicates project costs are higher than revenues. +PVWatts,Merchant Plant,211972144,6.05493,NA,; Warning: NPV is $-7.7984e+07. A negative NPV indicates project costs are higher than revenues. +PVWatts,Leveraged Partnership Flip,211972144,6.42751,4.32264,; Warning: IRR at end of analysis period is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: IRR in target year is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: NPV is $-4.10694e+07. A negative NPV indicates project costs are higher than revenues. +PVWatts,All Equity Partnership Flip,211972144,6.85332,4.32264,; Warning: IRR at end of analysis period is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: IRR in target year is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: NPV is $-1.69244e+07. A negative NPV indicates project costs are higher than revenues. Warning: NPV is $-3.09169e+07. A negative NPV indicates project costs are higher than revenues. +PVWatts,Sale Leaseback,211972144,7.55024,4.32264,; Warning: IRR at end of analysis period is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: NPV is $-6.44577e+07. A negative NPV indicates project costs are higher than revenues. +PVWatts,LCOE Calculator,211972144,NA,NA,; PVWatts,None,173951936,NA,NA,; High-X Concentrating PV,Single Owner,2.39082e+06,25.2519,25.9389,; High-X Concentrating PV,Merchant Plant,2.39082e+06,22.4433,NA,; Warning: IRR at end of analysis period is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: IRR in target year is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: NPV is $-4.61981e+06. A negative NPV indicates project costs are higher than revenues. @@ -41,12 +41,12 @@ PV Battery,Sale Leaseback,231595056,11.9576,9.7153,; Warning: IRR at end of anal PVWatts Battery,Residential,13799.1,22.8225,NA,; PVWatts Battery,Commercial,931773,9.09694,NA,; PVWatts Battery,Third Party,13799.1,NA,NA,; -PVWatts Battery,Host Developer,931773,16.2293,16.2095,; Warning: NPV is $-1736.75. A negative NPV indicates project costs are higher than revenues. -PVWatts Battery,Single Owner,213147984,11.644,9.77369,; Warning: NPV is $-3.75547e+07. A negative NPV indicates project costs are higher than revenues. -PVWatts Battery,Merchant Plant,207478832,37.6886,NA,; Warning: IRR at end of analysis period is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: IRR in target year is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: NPV is $-6.69017e+08. A negative NPV indicates project costs are higher than revenues. Warning: Debt percent is -218.744. A debt percent less than 0% may indicate the mininum EBITDA cannot support any debt in at least one year. -PVWatts Battery,Leveraged Partnership Flip,213147984,11.1737,9.77369,; Warning: IRR at end of analysis period is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: IRR in target year is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: NPV is $-2.75477e+07. A negative NPV indicates project costs are higher than revenues. -PVWatts Battery,All Equity Partnership Flip,213147984,12.9617,9.77369,; Warning: IRR at end of analysis period is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: IRR in target year is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: NPV is $-6.64267e+07. A negative NPV indicates project costs are higher than revenues. -PVWatts Battery,Sale Leaseback,213147984,12.9066,9.77369,; Warning: IRR at end of analysis period is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: NPV is $-6.32827e+07. A negative NPV indicates project costs are higher than revenues. +PVWatts Battery,Host Developer,931773,16.2293,16.2095,; Warning: NPV is $-1736.73. A negative NPV indicates project costs are higher than revenues. +PVWatts Battery,Single Owner,205381584,12.0129,9.82049,; Warning: IRR in target year is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: NPV is $-4.23862e+07. A negative NPV indicates project costs are higher than revenues. +PVWatts Battery,Merchant Plant,199956368,39.1307,NA,; Warning: IRR at end of analysis period is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: IRR in target year is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: NPV is $-6.70259e+08. A negative NPV indicates project costs are higher than revenues. Warning: Debt percent is -219.413. A debt percent less than 0% may indicate the mininum EBITDA cannot support any debt in at least one year. +PVWatts Battery,Leveraged Partnership Flip,205381584,11.5681,9.82049,; Warning: IRR at end of analysis period is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: IRR in target year is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: NPV is $-3.31104e+07. A negative NPV indicates project costs are higher than revenues. +PVWatts Battery,All Equity Partnership Flip,205381584,13.3304,9.82049,; Warning: IRR at end of analysis period is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: IRR in target year is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: NPV is $-7.01953e+07. A negative NPV indicates project costs are higher than revenues. +PVWatts Battery,Sale Leaseback,205381584,13.3169,9.82049,; Warning: IRR at end of analysis period is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: NPV is $-6.79729e+07. A negative NPV indicates project costs are higher than revenues. Custom Generation Battery,Residential,13415.9,33.0165,NA,; Custom Generation Battery,Commercial,359934,29.8962,NA,; Custom Generation Battery,Third Party,6693.07,NA,NA,; @@ -65,8 +65,8 @@ Standalone Battery,Merchant Plant,-6.8282e+06,27.1516,NA,; Warning: NPV is $-8.6 Standalone Battery,Leveraged Partnership Flip,-6.8282e+06,74.8038,72.8932,; Warning: IRR at end of analysis period is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: IRR in target year is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: NPV is $-9.85039e+06. A negative NPV indicates project costs are higher than revenues. Standalone Battery,All Equity Partnership Flip,-6.8282e+06,79.0515,72.8932,; Warning: IRR at end of analysis period is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: IRR in target year is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: NPV is $-3.35545e+07. A negative NPV indicates project costs are higher than revenues. Standalone Battery,Sale Leaseback,-6.8282e+06,75.2289,72.8932,; Warning: IRR at end of analysis period is not a number (NaN). This can indicate that revenues are too low to cover costs, or that they are excessively high compared to costs. Warning: NPV is $-1.44754e+07. A negative NPV indicates project costs are higher than revenues. Warning: NPV is $-8.19532e+07. A negative NPV indicates project costs are higher than revenues. -ETES,Single Owner,-466574464,17.2887,7.40497,; -PTES,Single Owner,-197596064,21.5721,10.3676,; +ETES,Single Owner,-467612160,17.2703,7.39986,; +PTES,Single Owner,-197600416,21.571,10.3673,; Physical Trough,Single Owner,377429056,17.5683,14.5131,; Physical Trough,Merchant Plant,377429056,16.1805,NA,; Physical Trough,Leveraged Partnership Flip,377429056,17.9196,14.5131,; @@ -110,8 +110,8 @@ Generic CSP System,All Equity Partnership Flip,592360448,15.1957,11.2639,; Warni Generic CSP System,Sale Leaseback,592360448,15.3777,11.2639,; Warning: NPV is $-2.40267e+08. A negative NPV indicates project costs are higher than revenues. Notice: time 0.00 { Generic solar model 2 }:\ The interpolation code must be 1 (interpolate) or 2 (nearest neighbor)The input value was 0, so it was reset to 1 Generic CSP System,LCOE Calculator,592360448,NA,NA,; Notice: time 0.00 { Generic solar model 2 }:\ The interpolation code must be 1 (interpolate) or 2 (nearest neighbor)The input value was 0, so it was reset to 1 Generic CSP System,None,592360448,NA,NA,; Notice: time 0.00 { Generic solar model 2 }:\ The interpolation code must be 1 (interpolate) or 2 (nearest neighbor)The input value was 0, so it was reset to 1 -MSPT IPH,None,1497518720,NA,NA,; -MSPT IPH,LCOH Calculator,1497518720,NA,NA,; +MSPT IPH,None,1497518592,NA,NA,; +MSPT IPH,LCOH Calculator,1497518592,NA,NA,; MSPT IPH,Single Owner,1550386816,6.10372,6.83681,; Notice: At time = 6087 CR_ON__PC_RM_HI__TES_FULL__AUX_OFF converged to a PC thermal power of 278.765 MWt less than the target of 279.126 MWt. Physical Trough IPH,None,20899050,NA,NA,; Physical Trough IPH,LCOH Calculator,20899050,NA,NA,; @@ -170,12 +170,12 @@ Custom Generation Profile,All Equity Partnership Flip,756864000,17.9669,25.9936, Custom Generation Profile,Sale Leaseback,756864000,17.6217,25.9936,; Warning: IRR at end of analysis period is 75.0978%. A high IRR may indicate a project with unrealistically high returns. Warning: IRR in target year is 75.097%. A high IRR may indicate a project with unrealistically high returns. Warning: NPV is $-5.31498e+07. A negative NPV indicates project costs are higher than revenues. Custom Generation Profile,LCOE Calculator,756864000,NA,NA,; Custom Generation Profile,None,756864000,NA,NA,; -PVWatts Wind Battery Hybrid,Single Owner,579291776,10.9026,6.18589,; Notice: Simulation time step is 60 minutes for pvwattsv8. Notice: Simulation time step is 60 minutes for windpower. +PVWatts Wind Battery Hybrid,Single Owner,571509504,11.0465,6.19288,; Notice: Simulation time step is 60 minutes for pvwattsv8. Notice: Simulation time step is 60 minutes for windpower. PVWatts Wind Battery Hybrid,Host Developer,1119067,18.5215,16.5322,; Notice: Simulation time step is 60 minutes for pvwattsv8. Notice: Simulation time step is 60 minutes for windpower. -PVWatts Wind FuelCell Battery Hybrid,Single Owner,581318016,11.2221,6.09623,; Notice: Simulation time step is 60 minutes for pvwattsv8. Notice: Simulation time step is 60 minutes for windpower. +PVWatts Wind FuelCell Battery Hybrid,Single Owner,574976896,11.3549,6.10072,; Notice: Simulation time step is 60 minutes for pvwattsv8. Notice: Simulation time step is 60 minutes for windpower. PVWatts Wind FuelCell Battery Hybrid,Host Developer,2.68756e+06,46.9226,47.7039,; Notice: Simulation time step is 60 minutes for pvwattsv8. Notice: Simulation time step is 60 minutes for windpower. Photovoltaic Wind Battery Hybrid,Single Owner,601657408,10.325,5.92081,; Notice: Simulation time step is 60 minutes for pvsamv1. Notice: Simulation time step is 60 minutes for windpower. Photovoltaic Wind Battery Hybrid,Host Developer,1.30379e+06,15.4337,16.5645,; Notice: Simulation time step is 60 minutes for pvsamv1. Notice: Simulation time step is 60 minutes for windpower. -CustomGeneration PVWatts Wind FuelCell Battery Hybrid,Single Owner,1340132352,12.5436,5.87576,; Notice: Simulation time step is 60 minutes for custom_generation. Notice: Simulation time step is 60 minutes for pvwattsv8. Notice: Simulation time step is 60 minutes for windpower. +CustomGeneration PVWatts Wind FuelCell Battery Hybrid,Single Owner,1332349312,12.6134,5.87734,; Notice: Simulation time step is 60 minutes for custom_generation. Notice: Simulation time step is 60 minutes for pvwattsv8. Notice: Simulation time step is 60 minutes for windpower. CustomGeneration PVWatts Wind FuelCell Battery Hybrid,Host Developer,759754816,14.997,15.0853,; Notice: Simulation time step is 60 minutes for custom_generation. Notice: Simulation time step is 60 minutes for pvwattsv8. Notice: Simulation time step is 60 minutes for windpower. final_configuration_eof,none,NA,NA,NA,